Leeb Fruit Orchard : By Architects Collective

Wiener Strasse 40, A-7161 St. Andrä am Zicksee, Austria
Architects Collective
Post By:Kitticoon Poopong
Photo © Courtesy of Architects Collective
Austrian architect Architects Collective recently has completed the fruit production facility for the Leeb Fruit Orchard. It was built in “passive house” standard by the prefabricated structure, wall and roof elements which were primarily constructed using renewable and recycled materials.
Photo © Courtesy of Architects Collective

Photo © Courtesy of Architects Collective

Project description by Architects Collective
The new production facility for the Leeb Fruit Orchard consists of a large main shed with cold storage and a fruit shop with adjoining spaces. The prefabricated structure was built within four months and the fruit shop with adjoining spaces were constructed in “passive house” standard and as self-supporting prefabricated wall and roof elements.
Photo © Courtesy of Architects Collective

Photo © Courtesy of Architects Collective
The main shed consists of a wooden frame construction with prefabricated insulated wooden box frames and is not heated. The facade of the entire building is made of OSB panels and varnished in brown and green colors. Two 5 x 6 m sliding doors transform the building from a closed wooden box into a complex architectural composition revealing views into the building and the shop. This gesture is reminiscent of a market stall and was inspired by the client’s first ideas for the building.
Photo © Courtesy of Architects Collective
Environmental and sustainable aspects of the planning, construction and maintenance of the building were particularly important to the owners Vera and Albert Leeb. The structure was primarily constructed using renewable and recycled materials as well as upcycling products for the furniture.
Photo © Courtesy of Architects Collective
The fruit shop is oriented to the main street with a continuous panorama window with triple-panel glass facing southwest. It is shaded by several large folding aluminum frames which are covered by used advertising banners protecting the interior from overheating in summer.
Photo © Courtesy of Architects Collective

Photo © Courtesy of Architects Collective
Old bicycle inner tubes were converted to spherical ceiling lights, used laminated wood panels were converted into shelves and cupboards and the sales desk was covered with used printer plates. Used concrete vineyard posts were used for the parking lot and other outdoor areas as pavement material allowing rainwater percolate. The rainwater of the roof is caught in two evaporation basins that are incorporated into the surrounding landscape.
Photo © Courtesy of Architects Collective

Photo © Courtesy of Architects Collective

Photo © Courtesy of Architects Collective

site plan--drawing Courtesy of Architects Collective

groung floor plan--drawing Courtesy of Architects Collective

roof plan--drawing Courtesy of Architects Collective

section A-A,B-B--drawing Courtesy of Architects Collective

section C-C--drawing Courtesy of Architects Collective

diagram--drawing Courtesy of Architects Collective
The people
Location:
Wiener Strasse 40,
A-7161 St. Andrä am Zicksee, Austria

Client:
Vera & Albert Leeb
Wiener Straße 40
A-7161 St. Andrä am Zicksee
+43 680 21 64 304

Architect: Architects Collective

Planning services: architectural planning
schematic design/design development/construction documents/site supervision

Team:
Andreas Frauscher, Richard Klinger, Mathias Leeb, Kurt Sattler

Construction company:
Subau Baugesellschaft
Hauptstraße 110
A-7111 Parndorf

Carpentry:
Weissenseer Holz-System-Bau
Weißensee Straße 1
A-9761 Greifenburg

Steel construction:
SK Stahlbau
Hosnedlgasse 35
A-1220 Wien

Furniture:
Gabarge Upcycling Design
Schleifmühlgasse 6
1040 Wien

Site area: 3500 m²
Floor area: 400 m²
Gross floor area: 450 m²
Gross floor area: 2.500 m³

Planning: 2008
Construction: 2009

Building cost: €350.000
Construction cost: €400.000 (building costs, interior, landscape)
Capital cost: €450.000 (building costs, interior, exterior, fees, other costs)

Energy data
Energy standard: passive house
Heating demand: 16.10 kWh / m² a
Heating load: 12.60 W / m²
Building airtightness n50: 0.26 1 / h
Wall, roof, floor: 0.10 W / m² K
Wood-aluminum windows: 0.75 W / m² K
Glass triple pane, Ug = 0,60 W / m² K, g-value = 52%
Ventilation: micro compact ventilation with heat pump
/